resin sealed cable connection
Resin Cable Joint Kit for Medium-Size Cable Connections
M11
This resin cable joint kit is designed for compatible four-core cable connections with cross-sectional areas ranging from 4 × 4 mm² to 4 × 10 mm².
With a listed cable diameter range of 14–26 mm, this kit combines a protective housing with auxiliary sealing materials to support cable joint preparation and insulation.
It is suitable for electrical installation, cable maintenance, and connection projects where the cable dimensions match the specified range.
Please verify the cable size and installation requirements before ordering.
Quantity

JINH M11 Resin Cable Joint Kit for Four-Core Cable Connections

Cable joints are an important part of electrical installation and maintenance. When two cable sections need to be connected, the joint must be properly prepared and protected according to the requirements of the application. Selecting a suitable cable joint kit helps installers work with compatible cable sizes and organize the materials required for the connection process.

The JINH M11 resin cable joint kit is designed for four-core cables with cross-sectional areas from 4 × 4 mm² to 4 × 10 mm². The specified maximum cable diameter range is 14–26 mm. These parameters help customers determine whether the M11 model is suitable for their cable before placing an order.

As part of the JINH M10–M15 cable joint kit series, M11 is intended for cable sizes larger than those covered by the M10 model. Its kit-based configuration provides a protective housing and associated sealing accessories to support the preparation of compatible cable joints.

1. Designed for 4 × 4–4 × 10 mm² Cables

Cable cross-sectional area and overall cable diameter are two important factors when selecting a resin cable joint kit. A cable may have the correct conductor cross-section but still be unsuitable if its outer diameter or the dimensions of the completed joint fall outside the product's specified range.

The JINH M11 supports the following listed cable specifications:

  • Cable cross-sectional area: 4 × 4 mm² to 4 × 10 mm²

  • Maximum cable diameter range: 14–26 mm

  • Cable configuration: Four-core cable, subject to confirmation of the actual cable construction and joint arrangement

  • Product type: Resin cable joint kit with protective housing and auxiliary sealing materials

The stated dimensions should be used as a starting point for product selection. Before ordering, confirm the actual cable outer diameter, conductor arrangement, connector dimensions, and the installation method required for the application.

2. Protective Housing and Included Accessories

The M11 product image shows a transparent, elongated protective housing supplied with a package of auxiliary materials. The pictured accessories include sealing-related components and insulating tape. These materials are intended to support the preparation and protection of the cable joint, subject to the manufacturer's instructions.

The protective housing provides an enclosure for the prepared connection. Its transparent structure allows the installer to see the position of the components during assembly. This can be useful when checking the joint arrangement before the specified sealing process is completed.

A kit-based product also makes it easier to prepare the required materials before work begins. Customers should confirm the final packing list and the function of each accessory with JINH, particularly when purchasing the product for a specific installation project.

3. Resin Sealing for Cable Connection Protection

Resin cable joint kits are used in applications where a cable connection requires additional insulation and sealing. The completed joint depends on several factors, including the quality of the electrical connection, correct positioning of the cable joint, proper use of the sealing materials, and compliance with the installation instructions.

For the M11, users should follow the supplied instructions for the specified resin or sealing compound, including preparation, mixing, application, and curing where applicable. The curing time and environmental limitations should be confirmed from the product documentation rather than assumed.

A resin-sealed cable joint kit should not be selected solely because it is described as a sealing product. The intended environment, required protection level, cable type, and applicable electrical standards must also be considered.

4. Main Product Features

Suitable for a defined cable size range
M11 is listed for four-core cable cross-sectional areas from 4 × 4 mm² to 4 × 10 mm², with a maximum cable diameter range of 14–26 mm. This provides a clear starting point for checking compatibility.

Protective housing design
The transparent housing encloses the prepared cable connection and allows visual inspection of component positioning during assembly.

Kit-based configuration
The product image shows the housing supplied alongside auxiliary sealing materials. The exact package contents should be verified against the manufacturer's packing information.

Supports organized cable joint preparation
The combined components help installers prepare the cable joint materials in advance, making the installation process easier to organize.

Part of the JINH M10–M15 series
The range includes models for different cable sizes. Customers can compare the specifications of M10, M11, M12, M13, M14, and M15 to identify the appropriate option for their application.

5. Typical Application Areas

Subject to the verified product ratings and installation requirements, the M11 may be considered for compatible cable jointing work in areas such as:

  • Electrical installation and maintenance

  • Cable connection and repair projects

  • Building electrical services

  • Equipment wiring and electrical assemblies

  • General cable joint preparation where the specified cable dimensions are met

The suitability of the product for a particular environment must be confirmed before use. Applications such as direct burial, permanent immersion, outdoor exposure, or use in demanding industrial conditions may require specific ratings or additional installation requirements. These capabilities should not be assumed without supporting technical documentation.

6. General Installation Guidelines

The following steps provide a general overview of cable joint preparation. The product-specific installation instructions take priority.

Step 1: Check cable compatibility
Confirm that the cable has four cores and falls within the listed cross-sectional area range of 4 × 4–4 × 10 mm². Check that its overall diameter is within the specified 14–26 mm range.

Step 2: Isolate the electrical supply
Disconnect the relevant circuit and verify that it is de-energized. Installation should be performed by a qualified person using appropriate safety procedures.

Step 3: Prepare the cable ends
Prepare the cable ends according to the specified method and use a suitable connector for the conductors. Check that the electrical connection is secure and that the assembled joint fits within the housing.

Step 4: Position the joint in the housing
Place the prepared cable connection in the protective housing as instructed. Arrange the accessories according to their intended functions.

Step 5: Complete the sealing process
If the kit includes a resin compound, prepare and apply it according to the manufacturer's instructions. Follow the specified filling and curing procedures.

Step 6: Inspect the finished joint
Allow the sealing material to complete the required curing process. Inspect the assembly and confirm that it meets the requirements of the intended installation before the circuit is returned to service.

7. How to Select the Right Model in the M10–M15 Series

The M10–M15 range covers different cable cross-sectional areas and cable diameter ranges. Choosing the correct model requires checking both the conductor size and the overall cable dimensions.

  • M10: 4 × 2.4–4 × 4 mm²; listed cable diameter range 7–16 mm

  • M11: 4 × 4–4 × 10 mm²; listed cable diameter range 14–26 mm

  • M12: 4 × 10–4 × 25 mm²; listed cable diameter range 14–34 mm

  • M13: 4 × 25–4 × 50 mm²; listed cable diameter range 21–43 mm

  • M14: 4 × 50–4 × 95 mm²; listed cable diameter range 28–48 mm

  • M15: 4 × 120–4 × 150 mm²; listed cable diameter range 36–70 mm

These ranges are based on the supplied product specification chart. Because some model ranges may overlap, do not select a model based on cable cross-section alone. Confirm the actual cable diameter, joint dimensions, and compatibility with the intended connection arrangement.

8. Why Choose JINH?

JINH is a Chinese manufacturer of electrical connection products with manufacturing experience dating back to 1997. Its product range includes terminal blocks, wire connectors, waterproof connectors, junction boxes, industrial plugs and sockets, cable glands, and related electrical accessories.

For customers sourcing cable joint kits, the M10–M15 series provides multiple model options for different cable sizes. JINH can help customers confirm model specifications and available product documentation before an order is placed.

Frequently Asked Questions

What cable size is the M11 resin cable joint kit designed for?
The supplied specification chart lists a cable cross-sectional area range of 4 × 4–4 × 10 mm² and a maximum cable diameter range of 14–26 mm.

Does M11 include a protective housing?
The product image shows a transparent protective housing and auxiliary sealing materials. Confirm the final packing list with JINH before ordering.

Is M11 suitable for every four-core cable?
No. The cable cross-section, overall diameter, connector dimensions, and joint arrangement must be compatible with the kit.

Can M11 be used for underground or underwater installations?
These applications require confirmation of the product's ratings and installation requirements. Do not assume suitability without the relevant technical documentation.

How can I confirm the correct model?
Provide the cable cross-sectional area, outer diameter, conductor configuration, and intended installation environment. JINH can help check the available model specifications.

Conclusion

The JINH M11 resin cable joint kit is designed for compatible four-core cable connections with cross-sectional areas from 4 × 4 mm² to 4 × 10 mm² and a listed cable diameter range of 14–26 mm. Its protective housing and accompanying sealing accessories provide a practical kit-based approach to cable joint preparation. Checking the cable dimensions and verified installation requirements before ordering helps ensure the model is suitable for the intended application.